當(dāng)前的位置:上海普譽首頁>產(chǎn)品中心 > 內(nèi)容
Acclaim混合基質(zhì)WAX-1色譜柱Acclaim混合基質(zhì)WAX-1色譜柱 其它-液相色譜
Acclaim混合基質(zhì)WAX-1色譜柱Acclaim混合基質(zhì)WAX-1色譜柱
- 產(chǎn)品綜述
Acclaim 混合基質(zhì)WAX-1色譜柱—難分離物質(zhì)輕松搞定!
Acclaim®混合基質(zhì)WAX 色譜柱是一款硅膠基質(zhì)固定相,同時具有疏水性和弱陰離子交換能力能力。能同時分析酸,堿,中性物質(zhì)。調(diào)整流動相能調(diào)節(jié)特定被分析物的選擇性
Reversed-phase and weak anion-exchange properties on a single column The novel column chemistry of the Acclaim Mixed-Mode WAX-1 results in a multimode separation mechanism including hydrophobic, anion-exchange, and cation-exclusion interactions.Consequently, retention of basic, neutral, and acidic molecules can be either independently or concurrently adjusted by changing ionic strength, pH, and organic solvent content in the mobile phase. • Adjustable selectivity • Selectivity orthogonal to reversed-phase (RP) columns • Ideal selectivity for anionic molecules • Simultaneous separation of acidic, basic, and neutral molecules • Multimode retention mechanisms: reversed- and normal phase, anion-exchange, cation-exclusion, and HILIC modes The Acclaim Mixed-Mode WAX-1 column combines hydrophobic and anion -exchange characteristics, on a 5 μm high-purity,porous silica with 120-Å diameter pores. Because of this unique chemistry, the Acclaim Mixed-Mode WAX-1 column also provides complimentary selectivity to C18 reversed-phase columns. Hydrophilic organic acids are often difficult to separate with common RP columns, since hydrophobic retention alone is inadequate to differentiate molecules with similar hydrophobicities.This can be overcome using the Acclaim Mixed-Mode WAX-1 column; it provides sufficient retention, and ideal selectivity for a variety of anionic molecules, even for weakly charged molecules. 訂購信息: Analytical Columns Acclaim Mixed-Mode WAX-1, 5 μm (4.6 × 250 mm)................................ 064985 Acclaim Mixed-Mode WAX-1, 5 μm (4.6 × 150 mm)................................ 064984 Acclaim Mixed-Mode WAX-1, 5 μm (2.1 × 150 mm)................................ 067084 Guard Columns Acclaim Mixed-Mode WAX-1, 5 μm Guard Cartridges (4.3 × 10 mm),2 each......... 064986 Acclaim Mixed-Mode WAX-1, 5 μm Guard Cartridges (2.1 × 10 mm),2 each......... 067085 Guard cartridges require holder. SST Guard Cartridge Holder..................................................... 059456 Guard to Analytical Column Coupler............................................. 059457 Guard Kit (Holder and Coupler)................................................. 059526 應(yīng)用譜圖:
|